SPECIFICATIONS FOR OPTIONAL FEATURES
MOTOR OPERATIONS to include high starting torque motor, reduction gearing, solenoid brake, limit switches for up and down door travel, emergency hand chain with electrical interlock to cut power to control switch when hand chain is engaged, magnetic relay starter with overload protection, internal pre-wiring to terminal block, three button station operating on a 24 volt control circuit. Motor is removable without affecting emergency hand chain operation. Wiring diagram provided.
REVERSING SAFETY DOOR EDGE to be furnished on motor operated doors. Upon contact with an obstruction this safety feature will stop the door and return it to fully open position.
BOTTOM ASTRAGAL as the still to be provided using tubular neoprene.
WINDLOCKS to be provided for doors exceeding 20 pounds per square foot windload with appropriate windlock guides.
SLOPING BOTTOM BARS to be furnished as indicated to suit sloped sill conditions.
ALL SEAL WEATHER DOOR to be provided with weather stripping around all edges, including guide weather stripping, bottom bar astragal, hood baffle and No. 5 slat.
SHOP COAT curtain and hoods shall be shop primed in addition to non-galvanized surfaces. A full range of powder coatings is also available.
VISION LITES, 1” x 5”, to be furnished at eye level, assemble consisting of 3 lites across - 5 slats high.
EXTERIOR MOUNTING with exterior hoods and operator covers, thru wall provided when operation is desired inside - door mounted on exterior.
GALVANIZING to be applied to guides, brakets and pipe shafting in addition to galvanized parts provided in standard specifications.
FACIAS AND SOFITS to be provided, if shown to be supplied by Mahon.
INSULATED SLATS shall be double faced galvanized and prime painted #4 slat with polyisocynurate.
STOPLOCK SAFETY BEARING to be furnished on motor operated doors to prevent doors from falling due to damage to motor operator, drive chain or pipe shaft.
WICKET DOORS are available. Call factory with your specifications.
CYLINDER LOCKING is to be provided on the bottom bar of the door. For motor operated doors, protective cut-out switches to be furnished.